Archive: futur300.zip The Handicap News BBS (1:141/420) 1-203-926-6168 (300 to 14,400 baud) Also anonymous ftp site "handicap.afd.olivetti.com" 129.189.4.184 inflating: readme Futura-TTY software for IBM-PC New Version 3.0 (October '93) Software Developer: Futura Wave Communications Norman Williams (c)Copyright 1990-1993. All Rights Reserved. Licensed Distributor: PHONE-TTY, Incorporated 202 Lexington Ave Hackensack, N.J. 07601 201-489-7889 (GUY-PTTY) Voice 201-489-7890 TTY 201-489-7891 FAX 201-489-3323 (GUY-DEAF) BBS Developed by Norman Williams, an award winning deaf Computer Scientist. Distributed by PHONE-TTY Incorporated, founded in 1969. Congratulations! Your search for the best in Deaf telecommunications is over. You can expect many years of pleasure and satisfaction calling TTY's or computers. Futura FUTURA III version 3.00 software is here and offers many features YOU suggested and many new original features you can't find anywhere else. This software works in 45.45 baud FUTURA to 300 baud ASCII with a PHONE-TTY CM-4 modem or a ULTRATEC Intele-modem, and any Hayes-compatible modem (in 300 baud ASCII only and not FUTURA mode). Please note that very few portable TTY's in the community have the ASCII option in the TTY's. This software will work with the Macintosh if you have the Intele-modem and a intermediate software called "SoftPC" or "SoftAT" software by Insignia Solutions, Inc. This software displays a instruction guide on the screen which makes it very easy to use. When used with the PHONE-TTY CM-4 modem, or Ultratec Intele- Modem, it allows your IBM compatible computer (an XT 8mhz 8088 up to a Pentium) to communicate with a Telecommunication Device for the Deaf, and another computer to access Deafnet, CompuServe, Gallaudet VAX and other bulletin board services. The software requires a 270k minimum memory, one serial port (COM1-4) and DOS or OS/2. It is very user friendly. It is very easy to install. A comprehensive User Guide book is supplied but not needed for beginners. NEW FEATURES FOR 3.0:  Jump into Futura from another program FAST (.2 seconds) when the telephone rings. TSR supported. Easy to setup. Uses only 7K RAM.  Enhanced telephone directory search for specific name or phone number string for fast dialing by name or number. Also helps to identify phone numbers.  Improved Caller ID Support-see caller's name and phone number from the source before answering! Keeps a log. This requires the ANI-232 Caller ID hardware and service with your local telephone company.  You can interrupt an ASCII conversation with a flashing "May I interrupt,please?" flag.  Identa Ring support with Phone-TTY CM-4 modem - available in some areas.  Pager support - Alerts your remote pager of new messages in computer Auto-answer.  Color/Wallpaper setup - larger dazzling selection of colors or wallpaper styles.  Conversation style selection - pick one of the four different Send/Receive screen appearance.  Send names and telephone numbers right from the telephone directory file while on-line.  Improved Windows compatibility - PIF file allows you to run Futura in Window environment.  Automatic hang up of the telephone call if Futura's keyboard is not used for fifteen minutes, and the conversation will be saved automatically.  OS/2 compatible. Futura now works in OS/2 evironment.  If left in Main Menu, Futura will turn on Auto-answer mode after designated number of rings.  Enhanced automatic action of just-completed FUTURA conversation. Setup option allows either erasing or saving of conversation text. Can be manually overridden whenever needed on all calls.  Touch tone dialing with Phone-TTY CM-4 modem using a secondary Hayes compatible modem.  Prefix dialing allows telephone directory file to be portable.  New and larger User's Guide book. USEFUL FEATURES: þ Auto-answer mode with "intelligent handshaking". Allow the computer to accept Baudot calls from a TTY, or ASCII terminals in Bell 103 mode in either Originate or Answer, 300 baud, half or full duplex modes. þ Allows auto-answer mode to be interrupted without being disconnected. þ Write files [download] to disk and record conversations while on line up to the capacity of the hard disk. þ Read and Send [upload] messages previously recorded on disk, in either ASCII or Baudot modes. þ Record date/time from the computer's internal clock/calendar. þ Log all incoming and outgoing data to the hard disk, floppy disk or printer. þ Display on screen help file for each function. þ Send pre-recorded message files by pressing one key. þ Supports monochrome and color monitors up to Super VGA color. þ Allows software to run in Windows environment, in multi-tasking mode. þ Allows co-existing with a 2400 or 9600 baud modem card. þ Caller-ID support. Display caller's phone number and name before you answer the call. Keeps a log of the last 100 calls. þ Scroll back and forth while on line during the entire conversation. þ Privacy screen to cover Auto-answer calls on the monitor. þ Screen saver to prevent monitor burnout from long idle. þ Large RINGING display when phone rings to attract attention. þ Filing conversations in selected "folders" for quick retrieval. þ Allow wide color set up by user for attractive 3-D effect. þ Contains alphanumeric 500 telephone directory file and allows auto dialing from this directory file. þ Allows dialing with words which will convert to numbers automatically; ie. GUY-DEAF to 489-3323. þ Allow remote retrieval of messages left for you in the Auto-Answer mode by using a secret password. þ Allows messages to be left in private mailboxes. þ Allows remote retrieval of telephone directory files. þ Announcement message can be changed remotely using a password command. þ Faster connection to Relay Center with macro key. þ Can switch between half duplex to full duplex ASCII or to 45 Baud FUTURA without being disconnected. þ On PBX systems, CM-4 modems allows transfer calls from one telephone to another telephone without being disconnected. ------------------------------------------------------------------------- WHAT IS A TDD? WHAT IS A TTY? TDD is an abbreviation of Telephone Device for the Deaf which is a communication device for the Deaf which may not be compatible with each other. In the "beginning", in 1968, all TTYs for the deaf were TELETYPE compatible, such as the model 12, 14, 15, 20, 28, 30, 31, 32, 42 which were manufactured by TeleTYpe Corporation. Communication products for the deaf that was not made by TELETYPE Corporation was referred to as a TDD in 1969. The first American portable TDD, the SCANATYPE, was made by ESSCO Corporation of New Jersey under contract with Lee Brody and dubbed a TDD by Betty Broecker of Philadelphia. Today, TELETYPE Corporation is no longer in operation. Deaf people communicate with others using the Baudot TELETYPE code, 5 bits, at 45.45 baud, since 1968. As the result of a popularity vote, a TDD is now called a FUTURA (TeleTYpe) to be used by everyone, deaf and hearing. Hayes compatible modems are NOT compatible with TTYs. This is due to different tones generated by the FUTURA modem which uses frequencies at 1400 Hz for mark and 1800 Hz for space. A Hayes compatible modem such as the Bell 103 modem (300 baud ASCII) generate tones in originate mode at 1270 Hz for mark and 1070 Hz for space while in answer mode, it is 2225 Hz for mark and 2025 Hz for space. Most of the TTY/TDD on the market do not have the ASCII option. So, you can see why a FUTURA modem for FUTURA communication is required for full access to the network. REQUIREMENTS: þ Phone-TTY CM-4 Modem (45.45 baud Baudot to 300 baud ASCII) or Ultratec Intele-Modem (45.45 baud Baudot to 300 baud ASCII) or Krown SM85H (45.45 baud Baudot only) or Hayes compatible modem (300 baud ASCII only) þ IBM XT (8 MHZ 8088 or better), AT, PS/2, 386, 486, up to the Pentium. þ LCD/Monochrome (laptop computer), Color Graphics Adapter (CGA), Enhanced Graphics Adapter (EGA), Multi-Color Graphics Array (MCGA), or Video Graphics Array (VGA). þ Serial Port (COM 1 - 4). þ 270K minimum free RAM. þ DOS version 2.0 or higher. OPTIONAL EQUIPMENT: þ ANI-232 Caller-ID modem INSTALLATION: Place this disk in drive A, type " A: " or in drive B, then type " B: "and press key, then type "INSTALL" and press . Follow the instructions on the screen. Do not use COPY commands to copy the files. It is not necessary to create batch file such as "FUTURA.BAT". LETS GET STARTED: Execute the program by typing "TTY" and press key at DOS prompt. Your best friend for learning how to use the program is to use in any part of the program. To press key, just press and hold the key while you press key. The is a help screen related to current functions. In other words, not all help screens are the same for each function. After playing with every command outlined in all help screens, you should be able to master this FUTURA program. When modem selection is set to "None", press to simulate other user's typing. This way you can try out the Futura-TTY software without a modem. With a Hayes compatible modem, you can try a call to a relay service or a Bulletin Board Service (BBS) in 300 baud ASCII. To jump-start from DOS prompt into the position you would like Futura to be, there are jump commands. This will work only if "C:\FUTURA" has been installed in path string command of AUTOEXEC.BAT file and if AUTOEXEC.BAT contains the string "SET FUTURA=C:\FUTURA". While your prompt on the screen reads such as "C:\>", you may type: þ FUTURA -TSR To turn on swapping for quick answering. þ FUTURA -A To ANSWER incoming call now. þ FUTURA -A< Fn > To ANSWER with < Fn >key [n=1..12] message. þ FUTURA -D To go to DIRECTORY now. þ FUTURA -M To go to MESSAGE CENTER now. þ FUTURA -M< n > To MESSAGE CENTER with < #n >key [n=1..3] message. þ FUTURA -Z To go to MAIN MENU now. þ FUTURA -MONOVGA To go to Mono-VGA screen color in laptop. þ FUTURA To go to Futura now. If you want to leave your computer in Auto-Answer mode for an extended period of time and you want to be sure that in case of temporary power failure, that Futura-TTY III is back in Auto-Answer mode when power is restored, you will want to include the command "FUTURA -M" on the last line of AUTOEXEC.BAT file. NINE FILES OF FUTURA-TTY III: þ FUTURA.EXE FUTURA program. þ DIRECTORY.TTY List of phone numbers & names. þ README This file. þ README.COM To read this file. þ EXAMPLE.TXT Practice file for sending to another TTY. þ INSTALL.EXE To install this program. þ HELP.TTY Help file. þ FUTURA.PIF For Windows 3.0 & 3.1 environment. þ FUTUR300.ZIP Trial version which may be distributed freely. (Needs to be uncompressed with PKUNZIP.EXE program which can be downloaded from many public BBS) This program contains the FUTUR300.ZIP file which may be freely distributed to anyone. This FUTUR300.ZIP file is a DEMO version. Feel free to upload this file to any public Bulletin Board System (BBS) that will accept it. To use this file yourself, uncompress the file with PKUNZIP.EXE program. If you need assistance on this, contact your dealer. FUTURA.PIF FILE FOR WINDOWS: 386/486 Computers with 2mb or more: The hot key for the program is . Use it whenever you are in Windows 3.0 or 3.1, FUTURA in Auto-Answer mode will run in background to take messages even if other program is running. This means you can operate another program and immediately switch to FUTURA-TTY program to answer the phone call when your telephone signaler flashes, then go back to where you left off. 286/8086 Computers: There is no hot key directly, but can use the key to rotate programs. FUTURA will not run in background due to CPU's limitations. DEMO VERSION OF FUTURA-TTY II: þ 5 minutes limit on FUTURA or 300 baud ASCII call, unlimited for 300 baud ASCII calls to a Futura-TTY dealer or user. þ Accepts only 1 message taking feature. þ Remote retrieval not supported. Demonstration of remote retrieval in Notes is supported. Directory is not supported. þ This Readme file. FULL VERSION OF FUTURA-TTY III: þ Comes with updated guide book and updated Readme file. þ Unlimited time on each call. þ Unlimited message taking. þ Remote retrieval is supported. þ And many many more NEW features as you will learn from using it. If you initiate a outgoing call with a PHONE-TTY CM-4 modem by dialing a number, watch the monitor (MON) light to observe if the line is busy or ringing and the carrier detect (C.D.) light. If the C.D. green light comes on, that means you have detected a ASCII handshake and you can expect a 300 baud ASCII response on your screen. If the C.D. green light does NOT come on and the MON light flickers as if there is a either voice or FUTURA response, then tap the space bar. If it is a FUTURA response, a tap on the space bar will cause your program to default to FUTURA (45.45 baud Baudot) mode and you will then be able to read the incoming message if it is also in 45.45 baud BAUDOT. If you have a ULTRATEC INTELE-MODEM and you have dialed a number,watch the monitor light (SIG) to note if line is busy or ringing. If there is no ASCII detection or handshake, the modem will default automatically to 45.45 baud Baudot mode. If you tap the space bar, it will default to 45.45 baud. If you set up FUTURA with either PHONE-TTY CM-4 or the ULTRATEC INTELE-MODEM to accept a call in Auto Answer mode in 300 baud ASCII mode and the incoming call is at 45.45 baud BAUDOT, the program will automatically default to 45.45 baud Baudot mode after a short delay. In the autoexec.bat file, be sure to set up the PATH string accurately which should be exactly as the example "PATH=C:\DOS;C:\FUTURA" etc... We noted that a improper PATH string caused the telephone to answer improperly. After you have corrected the PATH string, do a "cold boot" (Turn off the computer, wait ten seconds, then turn it on) in order to remove any "glitch" in the software. CALLER-ID MODEM You should be aware that Caller-ID service has to be ordered from your telephone company for which there is a small monthly charge. Caller-ID service is now available in more than 24 states. You should check to see if the service is available in your area before you purchase the Caller-ID modem. How To Install: The ANI-232 Caller-ID modem requires no battery. It is as small as a gender changer. It has a DB25F (25 pin) port on one end and a RJ11 jack on the other end. The RJ11 jack is to be connected with modular cord to the same telephone wall jack as the telephone modular cord from the PC/TTY modem using a "T" adapter. In other words, one phone line is shared with the FUTURA modem and the Caller-ID modem. The DB25F (25 pin) jack of the ANI-232 Caller-ID is to be connected to the next available serial port in back of the computer (CPU) that is not used. The selected Serial (COM) port must have a different IRQ Interrupt from the COM port used by any of the modems, mouse or other devices, internal or external. If the selected Serial port in back of the computer has nine (9) pins, you may have to use a gender changer adapter DB9M (9 pin male) to DB25F (25 pin female) to be placed between the Caller-ID and the 9 pin Serial port. Compatibility of serial ports: All IBM compatible personal computers may use up to four serial Communications (COM) ports - COM1, COM2, COM3, and COM4. The Caller-ID uses one of these ports. Other equipment, such as serial printers, serial mouse device, and TTY modem use these ports. Most computers are shipped with at least the first serial port COM1, already equipped with a serial connector (9 pin male or 25 pin male) for attaching an external device such as a serial mouse, a external modem, or a serial printer. Most internal Hayes compatible modem cards are set at the factory in the default position to use COM2. Check the modem manual. Some internal Hayes compatible modems allow four COM ports to be used but allow only two COM ports to be active at the same time with only two different IRQ interrupts. Example: Serial PortIRQ Serial Port Address (Hex) COM1 IRQ4 3F8 COM2 IRQ3 2F8 COM3 IRQ4 3E8 COM4 IRQ3 2E8 Some Hayes compatible modems allow configuration for IRQ5 for COM3 and IRQ7 for COM4 by changing jumper positions on the modem card to allow up to four COM ports to be active at the same time. Example: Serial PortIRQ Serial Port Address (Hex) COM1 IRQ4 3F8 COM2 IRQ3 2F8 COM3 IRQ5 3E8 COM4 IRQ7 2E8 Check your choice of communication software to see if it allows for use of IRQ5 and IRQ7. FUTURA-TTY III, PRODIGY and PROCOMM PLUS does allow use of IRQ5 and IRQ7 interrupts. Some communication programs such as PRODIGY in COM3 or COM4 will require users to specify the Serial Port Address (Hex) in setting up the software. All communications programs that use IRQs support those listed for COM1 and COM2, and most communication programs support the positions listed for COM3 or COM4. However, don't use the same IRQ number for two devices that you plan to operate at the same time, such as a Caller-ID modem at COM1 and a FUTURA modem at COM3, and both using IRQ4. You may want to check your computer to see if there are any conflicts of COM ports. One way is to purchase a software called CHECKIT from your local software store. This software will display which COM ports are in use and whether the IRQ Interrupt is shared with another device. You can share a Serial port with a Mouse device if the MOUSE program is not active at the same time. How to recognize a Serial Port: In back of the computer, the serial ports always have a MALE pin receptacle which may be either nine (9) pin or twenty-five (25) pin RS232 or both. (Exception: Radio Shack computers have FEMALE receptacles marked as Serial ports). A 25 pin FEMALE receptacle in the back of the computer is for use of a Parallel (Sometimes called a Centronics type) printer. Some computers allow installation of two parallel printers (LPT1 and LPT2) and both 25 pin FEMALE connectors in the back of the computer look alike. (Note that there are two types of printers, either a serial or the more popular parallel printer.) If you are using a FUTURA modem and a Caller-ID: If you are using the external Serial port for your external FUTURA modem, you may plug the Caller-ID modem into the second external Serial port. If you dont have a second Serial port, you will have to purchase a internal Serial Port card to put inside your computer. Your FUTURA modem would probably be configured as COM 1 (IRQ 4) and your Caller-ID would be COM 2 (IRQ 3). If you are using a FUTURA modem, a Hayes compatible modem, and a Caller-ID: If you have only one external Serial port and it is already used by your external FUTURA modem, and you already have a internal Hayes compatible modem card inside your computer, that means COM 1 (IRQ4) for FUTURA modem and COM 2 (IRQ3) for internal Hayes modem has already been taken up. To add the Caller-ID modem to the next available serial port, it will be necessary to add a internal Serial port card to occupy a slot inside your computer. This serial card may be limited to either COM 1 or COM 2. In this case, your internal Hayes compatible modem card must be changed for COM 3 (IRQ 5). Remember no two serial devices may have the same IRQ number. For your information, many brands of Hayes compatible modems do not have IRQ interrupts other than IRQ3 and IRQ4. Consult your dealer before purchasing the Hayes compatible modem. REVIEW: How to use Remote Retrieval of messages left in AutoAnswer: 1-While in the main menu, press for Setup menu. 2-While in the Setup window, press for Remote Retrieval setup. 3-Press to enable remote retrieval (CURRENT:ON) 4-Press

to change your password from PASSWORD to your choice. 5-Press to exit from the setup menu. 6-Press to exit to the main menu. 7-Press to message-taking position. From another location using a FUTURA or another computer, call the Futura-TTY program which is left in AutoAnswer mode and after you have read the outgoing message, type "PASSWORD?" or whatever you have installed. If you are using Futura-TTY to retrieve your message, your password must be different from the other Futura-TTY. Your password will show for a few seconds and then erase itself. You will then type "NEW GA". You will then read a short report of whatever foldername is on the FIRST line of the reviewing menu regardless of its foldername. The first line should be reserved for AUTO-ANSWER folder. It will ask you "Read it now YqN? GA" You will then type "YES GA". If you want to read the contents of a different folder, type "NEW foldername GA" or "OLD foldername GA". If you want a list of the foldernames, type "LIST GA". In the Review menu, if the first line foldername is not "Auto Answer folder" in the Review menu, press "1" to change the foldername, and type in the correction. Messages received and saved from Autoanswer mode is always stored in the first foldername regardless of the name given to it. If you want to look up a phone number of United Airline by remote control, you will type "PHONE UNITED GA" after you have used your password. To close the Remote Retrieval file, you will type "SK". To practice further, you should review the User's Guide on page 16-17 and press (Leave a note to a user window) to practice all the remote retrieval commands without using a second phone line. We want to thank the many FUTURA users who have written to us with suggestions and comments so that we can bring to you this new version 3.0. We will continue to listen to your comments so that the next version of FUTURA and this README file may include more of your suggestions. FREQUENTLY ASKED QUESTIONS: QUESTION: "My AutoAnswer is not working. Why?" ANSWER: You may have 1) installed the wrong modem cable and the ring detector line is not connected. The modem cable must have support pins #1-8, 20 & 22 wired. Ask for a standard IBM compatible modem cable to fit your serial port, in the back of your computer which may be either a 25 pin RS232 connector or a 9 pin D connector. If there are 25 wires in your serial modem cable, it is acceptable as long as there are no crossover or jumped connections. Some 25 pin cables may not have all the internal wires connected or may be defective. 2) no message in the Message-taking setup file. 3) too many telephones and telephone signalers on the same line. Telephone service normally has a limit of 5.0 REN which is equivalent to approximately 5 devices on the line. Beyond 5 devices, the phone will not ring. QUESTION: "Will Futura-TTY work with the Macintosh computer ?" ANSWER: Yes, provided you use a software with it that allows the Mac to operate in the "PC" environment. This software is called SoftPC by Insignia Solutions. QUESTION: "How can I install the new external modem when I have no available serial port?" ANSWER: You may need to install a inexpensive serial card inside the computer and set the COM port on the card so there will be no conflict. QUESTION: "Should I buy a Hayes compatible modem as a second modem?" ANSWER: Yes, but it will not be compatible with TTYS for the deaf. You can have different modems to co-exist in different ports. Very few TTYS purchased by the deaf community have the ASCII option in the FUTURA to accept 300 baud ASCII. We recommend a 2400 baud modem either internal or external for calling Prodigy with Prodigy software, or other bulletin boards with Procomm Plus software. FUTURA-TTY software cannot be used at higher speed than 300 baud ASCII and cannot be used to call Prodigy. Modem manufacturers have established compatibility standards so that all Hayes compatible modems at 2400 baud ASCII are compatible with each other. Hayes compatible modems from different manufacturers at 9600 baud ASCII are compatible in "most" cases but not in all cases. At higher speed than 9600 baud, to be compatible in most cases, it may be necessary to use a modem from the same manufacturer at both ends, the host and the caller. This will change in the near future. QUESTION: "I have a old IBM compatible computer that is a 4.77 MHZ 8088 system and it does not work well with FUTURA-TTY. Why? ANSWER: FUTURA-TTY software cannot dial properly with a slow 4.77 MHZ 8088 system. The computer must be at least a 8 MHZ 8088 or better. QUESTION: "I use FUTURA-TTY software with a business phone but I cannot dial out. Why? ANSWER: Some digital business telephones are restricted to digital tone dialer and does not accept pulse dialing. Be sure you have your telephone company install a dedicated analog line for both pulse and tone dialer with a RJ11 jack which is installed "before" the KSU box. To transfer a FUTURA call in Baudot or ASCII mode from one phone to a second phone, the first phone must be disconnected as soon as the second phone is answered. The ASCII carrier can be maintained only between two phones, not three. CM-4 modem is a pulse dialer and the Intel-modem is a tone dialer. Residential telephone service will accept either a pulse or tone dialer modem. The new version 3.0 of FUTURA-TTY to be announced soon will allow the CM-4 modem to dial very fast in tone-i dialer mode by incorporating the internal Hayes modem as a dialer. QUESTION: "I called home from my work to retrieve messages in AutoAnswer and found that it does not work. Why? ANSWER: If your "PASSWORD" in FUTURA software at work is the same "PASSWORD" in FUTURA software at home, it will not work. The "PASSWORD" must be different for each location. For technical assistance, contact the dealer from whom you purchased FUTURA-TTY. ------------------------------------------------------------------------------- ORDER FORM The following may be ordered from your dealer:_______________________________ COMPUTER MODEM and accessories: Quantity Price S/H [ ] PHONE-TTY CM-4 modem with Futura-TTY III & Manual 359.00 7.00 [ ] ULTRATEC Intele-modem with Futura-TTY III & Manual 389.00 7.00 [ ] FUTURA-TTY III software & Manual-Full Version 3.0 59.95 5.00 [ ] FUTURA-TTY III Demo software 5.00 3.00 [ ] ANI-232 Caller-ID modem with gender changer 125.00 5.00 [ ] FUTURA-TTY III Manual - Version 3.0 without software 5.00 3.00 [ ] Telephone "T" adapter 3.50 3.00 [ ] Modular telephone wire (6 ft) 2.50 3.00 [ ] Serial port (AT) internal card (1 or 2 serial port) 30.00 5.00 [ ] Cardinal 2400 baud Hayes modem (IRQ4 & IRQ3) 69.00 5.00 [ ] Robotics 2400 baud Hayes modem (IRQ4, IRQ3, IRQ5, IRQ7) 135.00 5.00 [ ] Serial cable for CM-4,6 ft,DB9F(9 pin) to DB25M(25 pin) 15.00 5.00 [ ] Serial cable for CM-4,6 ft,DB25F(25pin) to DB25M(25pin) 15.00 5.00 [ ] Serial cable for Intele-Modem,6 ft, DB9F(9 pin) to DB9M(9 pin) 15.00 5.00 [ ] Gender changer,9F(9pin) to 25M(25pin)(free with ANI232) 10.00 5.00 [ ] Gender changer for Intele-Modem,9M(9 pin) to 25F(25 pin) 10.00 5.00 Call your dealer to confirm total shipping cost of mixed orders. Overnight or second day delivery available. Quantity Size Personalized Futura-TTY License (Limited to 27 characters) [ ] [ ] 3.5 " disk otherwise "Single User only" if left blank: [ ] [ ] 5.25 " disk Licensed to : "________________________________________" Check the items you wish to order. [ ] Check or money order ($20 extra charge for bad checks)Total Amount:______________ [ ] CREDIT CARD No.______________________________________Expires__________ [ ] VISA [ ] MASTERCARD [ ] DISCOVER [ ] AMERICAN EXPRESS Signature___________________________________________ We ship software by US mail and all packages only by United Parcel Service which requires complete street address. Name_________________________________________Apt/Company_______________________ Address______________________________________ City_________________State_______ ZIP___________________ Telephone No.___________________________Country_________ Name of Computer____________________________ Model: [ ] XT-8088[ ] AT-286-___hz[ ] 386-___hz [ ] 486-___hz [ ] PS2-___hz October 1993: Prices and availability subject to change at any time.Call to